SLC 5/04 32K Controller 1747-L542
Brand: Allen-Bradley/Rockwell
Code: 1747-L542
For Use With = SLC 500 Series
Manufacturer Series = SLC 500
Input Type = Digital
Voltage Category = 5 → 24 V
Output Type = Digital
Communication Port Type = DH+; RS232
Program Capacity = 28000 Words
Programming Interface = Computer
Battery Backup = Yes
SLC500 Modular PLC CPU ‘s. The Allen-Bradley SLC 500 is a small chassis-based family of programmable controllers; discrete; analogue; and speciality I/O; and peripheral devices. The SLC 500 family delivers power and flexibility with a wide range of communication configurations; features; and memory options. The RSLogix 500 ladder logic programming package provides flexible editors; point-and-click I/O configuration; and a powerful database editor; as well as diagnostic and troubleshooting tools to help you save project development time and maximize productivity. With up to 64 K of configurable data/program memory available and over 60 types of I/O modules; as well as a choice of networking options; the SLC system provides a powerful solution for stand-alone or distributed industrial control. Features and Benefits of SLC500 series:. Powerful; yet affordable – SLC 500 programmable controllers provide excellent value with extensive capabilities to address a broad range of applications including material handling; HVAC control; high-speed assembly operations; small process control; simple motion control; and SCADA. Modularity – Modular processes; power supplies; I/O; memory options; and communication interfaces allow for a configurable and expandable system. You can configure your system for the number of I/O; the amount of memory; and the communication networks needed. Later; you can expand the system by adding I/O; memory; or communication interfaces. Advanced instruction set – Includes indirect addressing; high-level math capability; and computer instruction. Communication network versatility - Choose from onboard Ethernet; DH+; or DH-485; as well as options for ControlNet; DeviceNet; or Remote I/O communications. Windows programming software – RSLogix 500 programming software maximizes productivity by simplifying program development and troubleshooting Run; program and test modes Password protection Built-in RS-232/422/423 communication port LED status and battery low indicators Internal registers for CPU status; minor faults and diagnostic information CPU memory assigned to timers; counters and storage as required by the user Optional EEPROM memory back-up Battery supplied Operating temperature range 0 to 60°C 5 to 95% RH (non-condensing) Dimensions: H 145 x W 35 x D 142mm. Additional features:. 5/02 CPU: - Supports high-speed data module - Can handle 32-bit signed maths functions - Indexed addressing 5/03; 5/04 and 5/05 CPU Additional Features to 5/02: - Additional communication ports - DF1 half duplex master protocol provides control of SCADA networks over modems - Trigonometric and exponential maths functions - Real-time clock and key switch. System Configuration Instruction:. Select I/O modules required for application and rack(s) to accommodate them. The CPU takes the first slot. Select processor required considering instruction; memory size and communications options. Calculate total backplane current requirement for CPU and I/O modules for both 5Vdc and 24Vdc and select an appropriate power supply.
Manufacturer Series = SLC 500
Input Type = Digital
Voltage Category = 5 → 24 V
Output Type = Digital
Communication Port Type = DH+; RS232
Program Capacity = 28000 Words
Programming Interface = Computer
Battery Backup = Yes
SLC500 Modular PLC CPU ‘s. The Allen-Bradley SLC 500 is a small chassis-based family of programmable controllers; discrete; analogue; and speciality I/O; and peripheral devices. The SLC 500 family delivers power and flexibility with a wide range of communication configurations; features; and memory options. The RSLogix 500 ladder logic programming package provides flexible editors; point-and-click I/O configuration; and a powerful database editor; as well as diagnostic and troubleshooting tools to help you save project development time and maximize productivity. With up to 64 K of configurable data/program memory available and over 60 types of I/O modules; as well as a choice of networking options; the SLC system provides a powerful solution for stand-alone or distributed industrial control. Features and Benefits of SLC500 series:. Powerful; yet affordable – SLC 500 programmable controllers provide excellent value with extensive capabilities to address a broad range of applications including material handling; HVAC control; high-speed assembly operations; small process control; simple motion control; and SCADA. Modularity – Modular processes; power supplies; I/O; memory options; and communication interfaces allow for a configurable and expandable system. You can configure your system for the number of I/O; the amount of memory; and the communication networks needed. Later; you can expand the system by adding I/O; memory; or communication interfaces. Advanced instruction set – Includes indirect addressing; high-level math capability; and computer instruction. Communication network versatility - Choose from onboard Ethernet; DH+; or DH-485; as well as options for ControlNet; DeviceNet; or Remote I/O communications. Windows programming software – RSLogix 500 programming software maximizes productivity by simplifying program development and troubleshooting Run; program and test modes Password protection Built-in RS-232/422/423 communication port LED status and battery low indicators Internal registers for CPU status; minor faults and diagnostic information CPU memory assigned to timers; counters and storage as required by the user Optional EEPROM memory back-up Battery supplied Operating temperature range 0 to 60°C 5 to 95% RH (non-condensing) Dimensions: H 145 x W 35 x D 142mm. Additional features:. 5/02 CPU: - Supports high-speed data module - Can handle 32-bit signed maths functions - Indexed addressing 5/03; 5/04 and 5/05 CPU Additional Features to 5/02: - Additional communication ports - DF1 half duplex master protocol provides control of SCADA networks over modems - Trigonometric and exponential maths functions - Real-time clock and key switch. System Configuration Instruction:. Select I/O modules required for application and rack(s) to accommodate them. The CPU takes the first slot. Select processor required considering instruction; memory size and communications options. Calculate total backplane current requirement for CPU and I/O modules for both 5Vdc and 24Vdc and select an appropriate power supply.
Check out any spare parts and components from the Allen-Bradley/Rockwell catalog!
Do you want to order a SLC 5/04 32K Controller 1747-L542 with code: 1747-L542?
Leave your request on our website for immediate assistance!