Buy IFM Electronic AC2916

AC2916 - ecomat300-ProcessLine 4AI C IP69K

Code: AC2916
  • Specially for the use in wet areas of the food and beverage industry
  • Hygienic design without corners and edges
  • Resistant to high-pressure cleaning with aggressive cleaning agents
  • Clearly visible powerful LEDs for displaying operation, switching status and error
Application
Application hygienic and wet areas in the food industry
Electrical data
Operating voltage [V] 26.5...31.6 DC
Max. current consumption from AS-i [mA] 450
Reverse polarity protection yes
Inputs / outputs
Number of inputs and outputs Number of analogue inputs: 4
Inputs
Sensor supply of the inputs AS-i
Number of analogue inputs 4; (connection of 2- and 3-wire sensors)
Analogue input (current) [mA] 4...20
Max. voltage drop across load for nominal voltage [V] 10
Resolution of analogue input 1 bit = 1 µA
Precision analogue input [%] 0,5
Operating conditions
Ambient temperature [°C] -5...70
Storage temperature [°C] -25...85
Max. relative air humidity [%] 90; (non condensing)
Max. height above sea level [m] 2000
Protection IP 68; IP 69K
Tests / approvals
EMC
EN 62026-2
EN 61000-6-2
MTTF [years] 98
AS-i classification
AS-i version 2.11; 3.0
Extended addressing mode no
AS-i profile S-7.3.E
AS-i I/O configuration [hex] 7
AS-i ID code [hex] 3.E
AS-i certificate 101108
Mechanical data
Weight [g] 607
Dimensions [mm] Ø 137.3 / L = 80
Materials threaded bush: stainless steel (1.4404 / 316L); PC; O-ring: EPDM
Displays / operating elements
Display
analogue signal LED, yellow channels AI1...AI4
operation LED, green AS-i
errors LED, red
Electrical connection
Module connection M12
Accessories
Accessories (optional)
Protective cap: M12, E70297
Flat cable insulation displacement connector:, E70454
Torque wrench:, E70390
Flat cable insulation displacement connector:, E70453
Remarks
Remarks
When the sensors and actuators are supplied from AS-i the load must not exceed a maximum of 380 mA.
The load for an individual sensor connection must not exceed 200 mA.
There is an electrical connection between the sensor and AS-i.
MEW = % of the final value of the measuring range
Pack quantity 1 pcs.
Electrical connection - AS-i
Connector: 1 x M12; coding: A; Tightening torque: 1.2...1.4 Nm
Electrical connection - Process connection
Connector: 4 x M12; coding: A; Tightening torque: 1.2...1.4 Nm

Check out any spare parts and components from the IFM Electronic catalog!