Buy IFM Electronic AC5250

AC5250 - ecomat300-AirBox 5/2 bist. 2DI-Y IP67

Code: AC5250
  • For the decentralised triggering of cylinders and valve actuators
  • Combination of AS-i I/O module and solenoid valve
  • High energy efficiency due to decentralised application near the actuator
  • Reduced installation and wiring complexity
  • Easy toolless installation and wiring thanks to quick mounting technology
Application
Application field installation
Medium temperature [°C] -10...50
Electrical data
Operating voltage [V] 26.5...31.6 DC
Max. current consumption from AS-i [mA] 180
Inputs / outputs
Number of inputs and outputs Number of digital inputs: 2; Number of pneumatic outputs: 2
Inputs
Number of digital inputs 2
Input circuit of digital inputs PNP
Sensor supply of the inputs AS-i
Power supply [V] 20...30; (via flat cable)
Max. total current rating of inputs [mA] 100
Input current High [mA] 6...10
Input current Low [mA] 0...2
Switching level high [V] > 11
Digital inputs protected against short circuits yes
Outputs
Number of pneumatic outputs 2; (pneumatic NO/NC selectable output ; bistable)
Actuator supply outputs AS-i
Operating conditions
Ambient temperature [°C] -10...55
Protection IP 65; IP 67
Tests / approvals
EMC
EN 50295
IEC 61000-6-2
MTTF [years] 286
AS-i classification
AS-i version 2.11; 3.0
AS-i addressing addressing socket
Extended addressing mode no
AS-i profile S-3.F.F
AS-i I/O configuration [hex] 3
AS-i ID code [hex] F.F
Assignment of the data bits
data bit D0 D1 D2 D3
input 1 2 3 4
socket I-1/2 I-1/2 I-2 - -
pin 4 2 4 - -
pneumatic output - - 4 2
Mechanical data
Weight [g] 383
Type of mounting quick mounting
Materials PA; POM; piercing contacts: CuSn6 nickel-plated and tin-plated
Pneumatic system 1 x 5/2-way slide valve (free from overlapping); bistable
Operating pressure range [bar] 3...8
Operating pressure range [MPa] 0.3...0.8
Operating pressure range [psi] 43.5...116
Air flow at 6/5 bar [l/min] 500
Permissible compressed air non-lubricated compressed air class 6-3-1; lubricated compressed air class 6-3-4
Manual override pressing/releasing or pressing/turning/locking
Tube fittings 8 mm
Exhaust exhaust can be discharged through tube connection
Displays / operating elements
Display
operation LED, green
errors LED, red
function LED, yellow
Electrical connection
Module connection Flat cables
Accessories
Items supplied
lower part
Accessories (optional)
Mounting plate:, E74999
Module lower part:, E75000
Protective cap: M12, E73004
sealing plugs:, E75231
silencer:, E75232
Push-in L-fitting:, E75228
Push-in T-fitting:, E75227
Remarks
Remarks
If not pneumatically operated, E75231 sealing plug must be inserted.
Avoid ingress of dirt and dust.
Do not connect any of the following points to an external potential:
I-, I+, I1, I2
The connections are electrically connected with the AS-i cable.
Please see the notes on compressed air and EMC/ESD under "Downloads"
Pack quantity 1 pcs.
Electrical connection
Connection quick mounting technology for AS-i flat cable: ; three orientations possible
Connection Connector: M12
Diagrams and graphs
Pneumatic symbol
1 x 5/2-way slide valve (free from overlapping); bistable

Check out any spare parts and components from the IFM Electronic catalog!


Do you want to order a AC5250 - ecomat300-AirBox 5/2 bist. 2DI-Y IP67 with code: AC5250?


Leave your request on our website for immediate assistance!