SD0523 - efector300-SDD11DGXFPKG/US-100
Brand: IFM Electronic
Code: SD0523
- Precise measurement of flow, consumption and medium temperature
- High accuracy, repeatability and measurement dynamics
- For detecting compressed air in industrial use
- With switching output, analogue output and pulse output
- Adjustable to inside pipe diameters
Product characteristics
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | |||
---|---|---|---|---|
Measuring range |
| |||
Process connection | threaded connection G 1 internal thread |
Application
Installation | Adjustable to inside pipe diameters; (38...254 mm) |
---|---|
Media | compressed air |
Medium temperature [°C] | 0...60 |
Pressure rating [bar] | 16 |
Pressure rating [Mpa] | 1.6 |
Pressure rating [psi] | 232 |
MAWP (for applications according to CRN) [bar] | 16 |
Electrical data
Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | < 110 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1 |
Inputs / outputs
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
---|
Outputs
Total number of outputs | 2 |
---|---|
Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 500 |
Pulse output | consumed quantity meter |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range
Measuring range | Measuring/setting range; Flow monitoring; The values apply at: Ø 72 mm | |||
---|---|---|---|---|
Measuring range |
| |||
Display range |
| |||
Resolution |
| |||
Set point SP |
| |||
Reset point rP |
| |||
Analogue start point ASP |
| |||
Analogue end point AEP |
| |||
In steps of |
|
Pulse value | 1...1000 x 10³ |
---|---|
In steps of | 1 Nm³ |
Pulse length [s] | 0,7...2 (D = 72 mm) |
Measuring range [°C] | 0...60 |
---|---|
Display range [°C] | -12...72 |
Resolution [°C] | 0.2 |
Set point SP [°C] | 0.4...60 |
Reset point rP [°C] | 0.2...59.8 |
Analogue start point [°C] | 0...45 |
Analogue end point [°C] | 15...60 |
In steps of [°C] | 0.2 |
Accuracy / deviations
Repeatability [% of the measured value] | ± 1,5 |
---|---|
Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW); (D = 72mm, T = 22 °C; standard volume flow: 50...850 Nm³/h) |
Accuracy [K] | ± 2,5 (Q > 2 Nm³/h) |
---|
Response times
Response time [s] | 0.1; (dAP = 0) |
---|---|
Damping process value dAP in steps [s] | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
Dynamic response T05 / T09 [s] | 30 (Q > 2 Nm³/h) |
---|
Software / programming
Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser |
---|
Interfaces
Communication interface | IO-Link | ||||
---|---|---|---|---|---|
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
SDCI standard | IEC 61131-9 | ||||
Profiles | Smart Sensor: Process Data Variable; Device Identification | ||||
SIO mode | yes | ||||
Required master port type | A | ||||
Process data analogue | 3 | ||||
Process data binary | 2 | ||||
Min. process cycle time [ms] | 5 | ||||
Supported DeviceIDs |
|
Operating conditions
Ambient temperature [°C] | 0...60 |
---|---|
Storage temperature [°C] | -20...85 |
Max. relative air humidity [%] | 90 |
Protection | IP 65 |
Tests / approvals
EMC |
| ||||
---|---|---|---|---|---|
Vibration resistance |
| ||||
MTTF [years] | 213 |
Mechanical data
Weight [g] | 539.5 |
---|---|
Materials | PBT-GF20; PC; stainless steel (1.4301 / 304); FKM |
Materials (wetted parts) | stainless steel (316 / 1.4401); stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM |
Process connection | threaded connection G 1 internal thread |
Displays / operating elements
Display |
|
---|
Remarks
Remarks |
| ||
---|---|---|---|
Pack quantity | 1 pcs. |
Electrical connection
Connection | Connector: 1 x M12; coding: A |
---|
Diagrams and graphs
final value of the measuring range referred to the internal pipe diameter | |
---|
Check out any spare parts and components from the IFM Electronic catalog!
Do you want to order a SD0523 - efector300-SDD11DGXFPKG/US-100 with code: SD0523?
Leave your request on our website for immediate assistance!