Buy IFM Electronic SD2000

SD2000 - efector300-SDR21DGXFPKG/US-100

Code: SD2000
  • Precise measurement of flow, consumption and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For detecting compressed air in industrial use
  • With switching output, analogue output and pulse output
  • Clearly visible 4-digit LED display
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0.3...95.2 m/s 3...700 m³/h 0.04...11.66 m³/min
Process connection threaded connection R 2 DN50
Application
Application for industrial applications
Media compressed air
Note on media
air quality ISO 8573-1
class 141
class 344
Medium temperature [°C] 0...60
Pressure rating [bar] 16
Pressure rating [Mpa] 1.6
Electrical data
Operating voltage [V] 18...30 DC; (to SELV/PELV)
Current consumption [mA] < 110
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250; (per output)
Number of analogue outputs 1
Analogue current output [mA] 4...20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
0.3...95.2 m/s 3...700 m³/h 0.04...11.66 m³/min
Display range
0...114.2 m/s 0...840 m³/h 0...13.99 m³/min
Set point SP
0.7...95.2 m/s 5...700 m³/h 0.09...11.66 m³/min
Reset point rP
0.3...94.8 m/s 2...697 m³/h 0.04...11.61 m³/min
Analogue start point ASP
0...71.4 m/s 0...525 m³/h 0...8.75 m³/min
Analogue end point AEP
23.8...95.2 m/s 175...700 m³/h 2.91...11.66 m³/min
In steps of
0.1 m/s 1 m³/h 0.01 m³/min
Volumetric flow quantity monitoring
Pulse value 0.010...4000000 m³
In steps of 0.010 m³
Pulse length [s] 0,021...2
Temperature monitoring
Measuring range [°C] 0...60
Display range [°C] -12...72
Accuracy / deviations
Flow monitoring
Repeatability [% of the measured value] ± 1,5
Accuracy (in the measuring range) ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN50)
Temperature monitoring
Accuracy [K] ± 2; (medium flow in the limit area of the flow measurement range)
Response times
Flow monitoring
Response time [s] 0.1; (dAP = 0)
Damping process value dAP in steps [s] 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles no profile
SIO mode yes
Required master port type A
Process data analogue 3
Process data binary 2
Min. process cycle time [ms] 4.1
Supported DeviceIDs
Type of operation DeviceID
Default 270
Operating conditions
Ambient temperature [°C] 0...60
Storage temperature [°C] -20...85
Max. relative air humidity [%] 90
Protection IP 65
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
CPA approval
model number 002TG
accuracy class -
maximum allowable error ± 4 % FS
Q (min) 3 m³/h
Q (t) -
Q (max) 700 m³/h
Vibration resistance
DIN EN 68000-2-6 5 g (55...2000 Hz)
MTTF [years] 227
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 4313
Materials PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminium powder-coated
Materials (wetted parts) stainless steel (1.4301 / 304): ; FKM; ceramics: glass passivated; PEEK GF30; polyester; aluminium
Process connection threaded connection R 2 DN50
Displays / operating elements
Display
Display unit 5 x LED, green (Nm³/min, Nm³/h, Nm/s, Nm³, °C)
function display 1 x LED, green
switching status 2 x LED, yellow
measured values alphanumeric display, 4-digit
programming alphanumeric display, 4-digit
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
For information about installation and operation please see the operating instructions.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A

Check out any spare parts and components from the IFM Electronic catalog!


Do you want to order a SD2000 - efector300-SDR21DGXFPKG/US-100 with code: SD2000?


Leave your request on our website for immediate assistance!

OUR TOP BRANDS