SD6101 - efector300-SDN12DGXFPKG/US-100
Brand: IFM Electronic
Code: SD6101
- Precise measurement of flow, consumption and medium temperature
- High accuracy, repeatability and measurement dynamics
- For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2)
- With switching output, analogue output and pulse output
- Clearly visible 4-digit LED display
Product characteristics
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
---|---|
Process connection | threaded connection 1/2" NPT DN15 |
Measuring range |
|
---|
Measuring range |
|
---|
Measuring range |
|
---|
Application
Application | for industrial applications |
---|---|
Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2) |
Medium temperature [°F] | 32...140 |
Pressure rating [bar] | 16 |
Pressure rating [psi] | 232 |
MAWP (for applications according to CRN) [bar] | 16 |
Electrical data
Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | < 100 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1 |
Inputs / outputs
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
---|
Outputs
Total number of outputs | 2 |
---|---|
Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 500 |
Pulse output | consumed quantity meter |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range
Low flow cut-off LFC |
| |||
---|---|---|---|---|
Measuring dynamics | 1:300 |
Pulse value | 0.040...4 000 000 scf |
---|---|
In steps of | 0.020...1000 scf |
Pulse length [s] | 0,007...2 |
Measuring range |
| |||
---|---|---|---|---|
Display range |
| |||
Resolution |
| |||
Set point SP |
| |||
Reset point rP |
| |||
Analogue start point ASP |
| |||
Analogue end point AEP |
| |||
In steps of |
|
Measuring range |
| |||
---|---|---|---|---|
Display range |
| |||
Resolution |
| |||
Set point SP |
| |||
Reset point rP |
| |||
Analogue start point ASP |
| |||
Analogue end point AEP |
| |||
In steps of |
|
Measuring range |
| |||
---|---|---|---|---|
Display range |
| |||
Resolution |
| |||
Set point SP |
| |||
Reset point rP |
| |||
Analogue start point ASP |
| |||
Analogue end point AEP |
| |||
In steps of |
|
Measuring range [°F] | 32...140 |
---|---|
Display range [°F] | 10.5...161.5 |
Resolution [°F] | 0.5 |
Set point SP [°F] | 32.5...140 |
Reset point rP [°F] | 32...139.5 |
Analogue start point [°F] | 32...118.5 |
Analogue end point [°F] | 53.5...140 |
In steps of [°F] | 0.5 |
Accuracy / deviations
Repeatability [% of the measured value] | ± 1,5 |
---|---|
Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15) |
Accuracy [K] | ± 2; (medium flow in the limit area of the flow measurement range) |
---|
Response times
Response time [s] | 0.1; (dAP = 0) |
---|---|
Damping process value dAP in steps [s] | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
Software / programming
Parameter setting options | Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection |
---|
Interfaces
Communication interface | IO-Link | ||||
---|---|---|---|---|---|
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
SDCI standard | IEC 61131-9 | ||||
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||
SIO mode | yes | ||||
Required master port type | A | ||||
Process data analogue | 3 | ||||
Process data binary | 2 | ||||
Min. process cycle time [ms] | 4.1 | ||||
Supported DeviceIDs |
|
Operating conditions
Ambient temperature [°F] | 32...140 |
---|---|
Storage temperature [°F] | -4...185 |
Max. relative air humidity [%] | 90 |
Protection | IP 65 |
Tests / approvals
EMC |
| ||||||||
---|---|---|---|---|---|---|---|---|---|
Vibration resistance |
| ||||||||
MTTF [years] | 227 | ||||||||
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
Weight [g] | 925.5 |
---|---|
Materials | PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM |
Materials (wetted parts) | stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised |
Process connection | threaded connection 1/2" NPT DN15 |
Displays / operating elements
Display |
|
---|