Buy IFM Electronic SD8100

SD8100 - efector300-SDR11DGXFPKG/US-100

Code: SD8100
  • Precise measurement of flow, consumption and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2)
  • With switching output, analogue output and pulse output
  • Clearly visible 4-digit LED display
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Process connection threaded connection R 1 DN25
Ar
Measuring range [m³/h] 1.2...366.6
CO2
Measuring range [m³/h] 0.8...223.6
N2
Measuring range [m³/h] 0.8...225
Application
Application for industrial applications
Media Argon (Ar); carbon dioxide (CO2); nitrogen (N2)
Medium temperature [°C] 0...60
Pressure rating [bar] 16
Pressure rating [Mpa] 1.6
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 100
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250; (per output)
Number of analogue outputs 1
Analogue current output [mA] 4...20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Low flow cut-off LFC [m³/h] < 3.8
Ar
Measuring range [m³/h] 1.2...366.6
Display range [m³/h] 0...440
Resolution [m³/h] 0.2
Set point SP [m³/h] 3.4...366.6
Reset point rP [m³/h] 1.8...365
Analogue start point ASP [m³/h] 0...293.2
Analogue end point AEP [m³/h] 73.4...366.6
In steps of [m³/h] 0.2
CO2
Measuring range [m³/h] 0.8...223.6
Display range [m³/h] 0...268.2
Resolution [m³/h] 0.2
Set point SP [m³/h] 2...223.6
Reset point rP [m³/h] 1...222.6
Analogue start point ASP [m³/h] 0...178.8
Analogue end point AEP [m³/h] 44.8...223.6
In steps of [m³/h] 0.2
Volumetric flow quantity monitoring
Pulse value 0.001...3 000 000 Nm³
In steps of 0.001...1000 Nm³
Pulse length [s] 0,004...2
N2
Measuring range [m³/h] 0.8...225
Display range [m³/h] 0...270
Resolution [m³/h] 0.2
Set point SP [m³/h] 2.2...225
Reset point rP [m³/h] 1...224
Analogue start point ASP [m³/h] 0...180
Analogue end point AEP [m³/h] 45...225
In steps of [m³/h] 0.2
Temperature monitoring
Measuring range [°C] 0...60
Display range [°C] -12...72
Resolution [°C] 0.2
Set point SP [°C] 0.4...60
Reset point rP [°C] 0...59.8
Analogue start point [°C] 0...48
Analogue end point [°C] 12...60
In steps of [°C] 0.2
Accuracy / deviations
Flow monitoring
Repeatability [% of the measured value] ± 1,5
Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN25)
Temperature monitoring
Accuracy [K] ± 2; (medium flow in the limit area of the flow measurement range)
Response times
Flow monitoring
Response time [s] 0.1; (dAP = 0)
Damping process value dAP in steps [s] 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 3
Process data binary 2
Min. process cycle time [ms] 4.1
Supported DeviceIDs
Type of operation DeviceID
Default 443
Operating conditions
Ambient temperature [°C] 0...60
Storage temperature [°C] -20...85
Max. relative air humidity [%] 90
Protection IP 65
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
CPA approval
model number 003TG
accuracy class -
maximum allowable error ± 7 % FS
Q (min) 0,8 m³/h (N2)
0,8 m³/h (CO2)
1,2 m³/h (Ar)
Q (t) -
Q (max) 225 m³/h (N2)
223,6 m³/h (CO2)
366,6 m³/h (Ar)
Vibration resistance
DIN EN 68000-2-6 5 g (55...2000 Hz)
MTTF [years] 224
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 2029
Materials PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminium powder-coated
Materials (wetted parts) stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK-GF30; polyester; aluminium
Process connection threaded connection R 1 DN25
Displays / operating elements
Display
Display unit 4 x LED, green (Nl/min, Nm³/h, Nm³, °C)
function display 1 x LED, yellow
switching status 2 x LED, yellow
measured values alphanumeric display, 4-digit
programming alphanumeric display, 4-digit
Display unit Nl/min; Nm³/h; Nm³; °C
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A

Check out any spare parts and components from the IFM Electronic catalog!


Do you want to order a SD8100 - efector300-SDR11DGXFPKG/US-100 with code: SD8100?


Leave your request on our website for immediate assistance!

OUR TOP BRANDS