SU8001 - efector300-SUR11HGBFRKG/W/US-100-IPF
Brand: IFM Electronic
Code: SU8001
- Precise measurement of flow, consumption and medium temperature
- Suitable for water, oils and glycol solutions
- For installation in pipes
- With switching output, analogue output and pulse output
- Clearly visible 4-digit LED display
Product characteristics
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||
---|---|---|---|
Measuring range |
| ||
Process connection | threaded connection G 1 flat seal |
Application
Special feature | Gold-plated contacts | ||
---|---|---|---|
Application | totaliser function; for industrial applications | ||
Installation | connection to pipe by means of an adapter | ||
Media | water; glycol solutions; coolants; oils | ||
Note on media |
| ||
Medium temperature [°F] | 14...176 | ||
Pressure rating [bar] | 16 | ||
Pressure rating [psi] | 232 |
Electrical data
Operating voltage [V] | 19...30 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | 100 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 10 |
Inputs / outputs
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
---|
Inputs
Inputs | counter reset |
---|
Outputs
Total number of outputs | 2 |
---|---|
Output signal | switching signal; analogue signal; pulse signal; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 500 |
Analogue voltage output [V] | 0...10; (scalable) |
Min. load resistance [Ω] | 2000 |
Pulse output | flow rate meter |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range
Measuring range |
| ||
---|---|---|---|
Display range |
| ||
Resolution |
| ||
Set point SP |
| ||
Reset point rP |
| ||
Analogue start point ASP |
| ||
Analogue end point AEP |
| ||
Max. flow rate |
| ||
In steps of |
|
Pulse value | 0.02...9000 * 10³ gal |
---|---|
In steps of | 0.02 gal |
Pulse length [s] | 0,3...2 |
Measuring range [°F] | 14...176 |
---|---|
Resolution [°F] | 0.5 |
Set point SP [°F] | 14.5...176 |
Reset point rP [°F] | 14...175.5 |
Analogue start point [°F] | 14...145.5 |
Analogue end point [°F] | 44.5...176 |
In steps of [°F] | 0.5 |
Accuracy / deviations
Accuracy (in the measuring range) | water: < ± (3 % MW + 0,2 % MEW); glycol (35 %), oil (viscosity 68 mm²/s at 40 °C): < ± (5 % MW + 0,5 % MEW) |
---|---|
Repeatability | 0,05 gpm; 3 gph |
Accuracy [K] | ± 5,4 (Q > 0,26 gpm) |
---|
Response times
Response time [s] | 0.25; (dAP = 0) |
---|---|
Delay time programmable dS, dr [s] | 0...50 |
Damping process value dAP [s] | 0...1 |
Dynamic response T05 / T09 [s] | T09 = 70 (Q > 1 gpm); (water) |
---|
Software / programming
Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
---|
Operating conditions
Ambient temperature [°F] | 14...140 |
---|---|
Storage temperature [°F] | -13...176 |
Protection | IP 67 |
Tests / approvals
EMC |
| ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Shock resistance |
| ||||||||||
Vibration resistance |
| ||||||||||
MTTF [years] | 185 | ||||||||||
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
Weight [g] | 1666.5 |
---|---|
Materials | housing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA |
Materials (wetted parts) | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 |
Process connection | threaded connection G 1 flat seal |
Displays / operating elements
Display |
|
---|
Accessories
Items supplied |
| ||||
---|---|---|---|---|---|
Accessories (optional) |
|
Remarks
Remarks |
| |||
---|---|---|---|---|
Pack quantity | 1 pcs. |
Electrical connection
Connection | Connector: 1 x M12; coding: A; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |
---|
Diagrams and graphs
Pressure loss |
|
---|
Check out any spare parts and components from the IFM Electronic catalog!
Do you want to order a SU8001 - efector300-SUR11HGBFRKG/W/US-100-IPF with code: SU8001?