SU9004 - efector300-SUR54HGB50KG/W/US-100-IPF
Brand: IFM Electronic
Code: SU9004
- Reliable detection of flow and medium temperature
- Suitable for water, oils and glycol solutions
- For installation in pipes
- With two scalable analogue outputs
- Clearly visible 4-digit LED display
Product characteristics
Number of inputs and outputs | Number of analogue outputs: 2 | ||
---|---|---|---|
Measuring range |
| ||
Process connection | threaded connection G 1 1/4 flat seal |
Application
Special feature | Gold-plated contacts | ||
---|---|---|---|
Application | for industrial applications | ||
Installation | connection to pipe by means of an adapter | ||
Media | water; glycol solutions; coolants; oils | ||
Note on media |
| ||
Medium temperature [°C] | -10...80 | ||
Pressure rating |
|
Electrical data
Operating voltage [V] | 19...30 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | 100 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 10 |
Inputs / outputs
Number of inputs and outputs | Number of analogue outputs: 2 |
---|
Outputs
Total number of outputs | 2 |
---|---|
Output signal | analogue signal |
Number of analogue outputs | 2 |
Analogue current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 500 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range
Measuring range |
| ||
---|---|---|---|
Display range |
| ||
Resolution |
| ||
Analogue start point ASP |
| ||
Analogue end point AEP |
| ||
Max. flow rate [l/min] | 220 | ||
In steps of |
|
Measuring range [°C] | -10...80 |
---|---|
Resolution [°C] | 0.2 |
Analogue start point [°C] | -10...62 |
Analogue end point [°C] | 8...80 |
In steps of [°C] | 0.2 |
Accuracy / deviations
Accuracy (in the measuring range) | water: < ± (3 % MW + 0,2 % MEW); glycol (35 %), oil (viscosity 68 mm²/s at 40 °C): < ± (8 % MW + 0,5 % MEW) |
---|---|
Repeatability | 1 l/min; 60 l/h; 0,05 gpm; 3 gph |
Accuracy [K] | ± 3 (Q > 20 l/min) |
---|
Response times
Response time [s] | 0.25; (dAP = 0) |
---|---|
Damping process value dAP [s] | 0...1 |
Dynamic response T05 / T09 [s] | T09 = 30 (Q > 20 l/min); (water) |
---|
Operating conditions
Ambient temperature [°C] | -10...60 |
---|---|
Storage temperature [°C] | -25...80 |
Protection | IP 67 |
Tests / approvals
EMC |
| ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CPA approval |
| ||||||||||||
Shock resistance |
| ||||||||||||
Vibration resistance |
| ||||||||||||
MTTF [years] | 203 | ||||||||||||
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
Weight [g] | 1883 |
---|---|
Materials | housing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA |
Materials (wetted parts) | stainless steel (1.4404 / 316L); FKM; PPS; Centellen 200 |
Process connection | threaded connection G 1 1/4 flat seal |
Displays / operating elements
Display |
| ||||||
---|---|---|---|---|---|---|---|
Display unit | l/min; m³/h; gpm; gph; °C; °F |
Accessories
Items supplied |
| ||
---|---|---|---|
Accessories (optional) |
|
Remarks
Remarks |
| |||
---|---|---|---|---|
Pack quantity | 1 pcs. |
Electrical connection
Connection | Connector: 1 x M12; coding: A; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |
---|
Diagrams and graphs
Pressure loss |
|
---|
Check out any spare parts and components from the IFM Electronic catalog!
Do you want to order a SU9004 - efector300-SUR54HGB50KG/W/US-100-IPF with code: SU9004?
Leave your request on our website for immediate assistance!