Active infrared scanner AIR30/32-UP-2526/A
Brand: Pepperl+Fuchs
Code: AIR30/32-UP-2526/A
Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Closing edge safety on automatic doors , Accurate beam alignment thanks to finely bundled light beam, Flush-mounted version with front cover, black, Function: Secure, Sensor principle: Active infrared scanner
Datasheet excerpt: Technical data of AIR30/32-UP-2526/A
Product Description |
---|
Single-beam light scanners with finely bundled light beam for monitoring main and ancillary closing edges |
General specifications | ||
---|---|---|
Detection range | factory setting: 100 ... 1600 mm on black | |
Detection range min. | 100 ... 1000 mm | |
Detection range max. | 100 ... 2500 mm | |
Light source | IRED | |
Light type | modulated infrared light | |
Black-white difference (6 %/90 %) | ≤ 400 mm at a distance of 2000 mm | |
Transmitter frequency | 1800 Hz | |
Operating mode | Background evaluation | |
Diameter of the light spot | 50 mm at 2000 mm sensor range | |
Opening angle | approx. 1.4 ° | |
Accessories provided | Swivel bracket, Mounting bracket | |
Functional safety related parameters | ||
MTTFd | 1050 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 90 % | |
Indicators/operating means | ||
Function indicator | LED red: lights up when output is active | |
Control elements | Sensing range adjuster, light-on/dark-on changeover switch | |
Factory setting | dark-on | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | 100 mA | |
Output | ||
Switching type | light/dark on, switchable / | |
Signal output | 1 PNP output, short-circuit protected, reverse polarity protected, open collector | |
Switching voltage | 30 V DC | |
Switching current | ≤ 200 mA | |
Response time | 50 ms | |
De-energized delay | approx. 200 ms | |
Standard conformity | ||
Standards | EN 60947-5-2 | |
Standards 2 | EN 61000-6-2 without EN 61000-4-5, EN 61000-4-11 | |
Standards 3 | EN 61000-6-3 | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP52 | |
Connection | fixed cable 1.5 m | |
Material | ||
Housing | plastic | |
Optical face | Luran® | |
Mass | 40 g |
Classifications
System | Classcode |
---|---|
ECLASS 13.0 | 27270913 |
ECLASS 12.0 | 27270913 |
ECLASS 11.0 | 27270913 |
ECLASS 10.0.1 | 27270913 |
ECLASS 9.0 | 27270913 |
ECLASS 8.0 | 27270913 |
ECLASS 5.1 | 27270903 |
ETIM 9.0 | EC002550 |
ETIM 8.0 | EC002550 |
ETIM 7.0 | EC002550 |
ETIM 6.0 | EC002550 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!