Background suppression sensor MLV41-8-H-350-RT/25/115/136
Brand: Pepperl+Fuchs
Code: MLV41-8-H-350-RT/25/115/136
Background suppression sensor in corrosion-resistant metal housing, 350 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Rugged series in corrosion-resistant metal housing, Reliable detection of all surfaces, independent of color and structure, Minimal black-white difference, Precision background suppression, adjustable, Extremely high switching frequency
Datasheet excerpt: Technical data of MLV41-8-H-350-RT/25/115/136
Product Description |
---|
Background suppression sensor in corrosion-resistant metal housing, 350 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable |
General specifications | ||
---|---|---|
Detection range | 50 ... 350 mm , adjustable | |
Detection range min. | 10 ... 50 mm | |
Detection range max. | 30 ... 350 mm | |
Adjustment range | 50 ... 350 mm | |
Background suppression | + 10 % of the upper limit of the detection range | |
Light source | LED | |
Light type | modulated visible red light , 660 nm | |
Black-white difference (6 %/90 %) | < 15 % at 350 mm | |
Diameter of the light spot | approx. 8 mm at 350 mm sensor range | |
Opening angle | 1.5 ° | |
Ambient light limit | 40000 Lux | |
Functional safety related parameters | ||
MTTFd | 1260 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green, statically lit Power on , Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) , short-circuit : LED green flashing (approx. 4 Hz) | |
Function indicator | 2 LEDs yellow ON: object inside the scanning range OFF: object outside the scanning range | |
Control elements | Sensing range adjuster | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | max. 25 mA | |
Output | ||
Signal output | 2 push-pull (4 in 1) outputs, complementary, short-circuit proof, reverse polarity protected | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA | |
Voltage drop | ≤ 2.5 V DC | |
Switching frequency | 1000 Hz | |
Response time | 0.5 ms | |
Conformity | ||
Product standard | EN 60947-5-2 | |
Approvals and certificates | ||
Protection class | II, rated voltage ≤ 50 V AC with pollution degree 1-2 according to IEC 60664-1 , functional insulation acc. to DIN EN 50178 | |
UL approval | cULus Listed 57M3 (Only in association with UL Class 2 power supply; Type 1 enclosure) | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 75 °C (-40 ... 167 °F) | |
Mechanical specifications | ||
Housing width | 31 mm | |
Housing height | 56.5 mm | |
Housing depth | 13.6 mm | |
Degree of protection | IP67 | |
Connection | 2 m fixed cable | |
Material | ||
Housing | Aluminum , Delta-Seal coated | |
Optical face | glass pane | |
Mass | 100 g |
Classifications
System | Classcode |
---|---|
ECLASS 13.0 | 27270903 |
ECLASS 12.0 | 27270903 |
ECLASS 11.0 | 27270904 |
ECLASS 10.0.1 | 27270904 |
ECLASS 9.0 | 27270904 |
ECLASS 8.0 | 27270904 |
ECLASS 5.1 | 27270904 |
ETIM 9.0 | EC002719 |
ETIM 8.0 | EC002719 |
ETIM 7.0 | EC002719 |
ETIM 6.0 | EC002719 |
ETIM 5.0 | EC002719 |
UNSPSC 12.1 | 39121528 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!
Do you want to order a Background suppression sensor MLV41-8-H-350-RT/25/115/136 with code: MLV41-8-H-350-RT/25/115/136?
Leave your request on our website for immediate assistance!