Ultrasonic sensor UB2000-F54-U-V15
Brand: Pepperl+Fuchs
Code: UB2000-F54-U-V15
Single head system, Analog output 0 ... 10 V, Measuring window adjustable, Program input, Series: -F54, Operating voltage: 15 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABS
Datasheet excerpt: Technical data of UB2000-F54-U-V15
Product Description |
---|
Single head system |
General specifications | ||
---|---|---|
Sensing range | 80 ... 2000 mm | |
Adjustment range | 100 ... 2000 mm | |
Dead band | 0 ... 80 mm | |
Standard target plate | 100 mm x 100 mm | |
Transducer frequency | approx. 175 kHz | |
Response delay | ≤ 150 ms | |
Indicators/operating means | ||
LED green | solid green: monitoring system green flashing: program function | |
LED yellow | solid yellow: object in the evaluation range yellow, flashing: program function, object detected | |
LED red | flashing: normal mode: error Program function: no object detected permanently: Program mode, object uncertain | |
Electrical specifications | ||
Operating voltage | 15 ... 30 V DC , ripple 10 %SS | |
No-load supply current | ≤ 55 mA | |
Input/Output | ||
Synchronization | 1 synchronous input 0-level: -UB...+1 V 1-level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: 0,1 ... 28 ms | |
Synchronization frequency | ||
Common mode operation | max. 33 Hz | |
Multiplex operation | ≤ 33 / n Hz, n = number of sensors | |
Input | ||
Input type | 1 program input lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s | |
Output | ||
Output type | 1 analog output 0 ... 10 V | |
Default setting | evaluation limit A1: 100 mm evaluation limit A2: 2000 mm | |
Resolution | 0.47 mm | |
Deviation of the characteristic curve | ± 1 % of full-scale value | |
Repeat accuracy | ± 0.1 % of full-scale value | |
Load impedance | ≥ 1 kOhm | |
Temperature influence | ± 1.5 % of full-scale value | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector plug M12 x 1 , 5-pin | |
Degree of protection | IP65 | |
Material | ||
Housing | ABS | |
Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam | |
Mass | 100 g |
Classifications
System | Classcode |
---|---|
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!
Do you want to order a Ultrasonic sensor UB2000-F54-U-V15 with code: UB2000-F54-U-V15?