Ultrasonic sensor UB500-18GM40A-I-V1-Y70103911
Brand: Pepperl+Fuchs
Code: UB500-18GM40A-I-V1-Y70103911
Single head system, Short design, 40 mm, Function indicators visible from all directions, Analog output 4 mA ... 20 mA, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, short-circuit/overload protected, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 4-pin
Datasheet excerpt: Technical data of UB500-18GM40A-I-V1-Y70103911
Product Description |
---|
Single head system |
General specifications | ||
---|---|---|
Sensing range | 40 ... 500 mm | |
Adjustment range | 40 ... 500 mm | |
Dead band | 0 ... 35 mm | |
Standard target plate | 100 mm x 100 mm | |
Transducer frequency | approx. 390 kHz | |
Response delay | approx. 50 ms | |
Indicators/operating means | ||
LED green | Power on | |
LED yellow | solid yellow: object in the evaluation range yellow, flashing: program function, object detected | |
LED red | solid red: Error red, flashing: program function, object not detected | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC , ripple 10 %SS | |
No-load supply current | ≤ 20 mA | |
Input | ||
Input type | 1 program input lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s | |
Output | ||
Output type | 1 analog output 4 ... 20 mA, short-circuit/overload protected | |
Default setting | evaluation limit A1: 40 mm evaluation limit A2: 420 mm | |
Resolution | 0.4 mm at max. sensing range | |
Deviation of the characteristic curve | ± 2 % of full-scale value | |
Repeat accuracy | ± 1 % of full-scale value | |
Load impedance | 0 ... 300 Ω at UB > 10 V; 0 ... 500 Ω at UB > 15 V | |
Temperature influence | ± 3 % of full-scale value | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
Approvals and certificates | ||
EAC conformity | TR CU 020/2011 TR CU 037/2016 | |
UL approval | cULus Listed, Class 2 Power Source | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 50 °C (-13 ... 122 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector plug M12 x 1 , 4-pin | |
Housing diameter | 18 mm | |
Degree of protection | IP67 | |
Material | ||
Housing | brass, nickel-plated | |
Transducer | epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT | |
Mass | 25 g |
Classifications
System | Classcode |
---|---|
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!
Do you want to order a Ultrasonic sensor UB500-18GM40A-I-V1-Y70103911 with code: UB500-18GM40A-I-V1-Y70103911?
Leave your request on our website for immediate assistance!