Ultrasonic sensor UC4000-L2M-B16-0,3M-DT6P-M
Brand: Pepperl+Fuchs
Code: UC4000-L2M-B16-0,3M-DT6P-M
Single head system, CANopen interface, E1-Type approval, High EMC resistance, Series: -L2M, Interface type: CAN, Communication protocol: CANopen, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-069608, Connection type: fixed cable with plug, Housing: PA-GF35, Connection assembly: Deutsch connector DT04-6P-CE02
Deutsch contact 1060-16-0622
Deutsch wedge W6P
Datasheet excerpt: Technical data of UC4000-L2M-B16-0,3M-DT6P-M
Product Description |
---|
Single head system |
General specifications | ||
---|---|---|
Sensing range | 200 ... 4000 mm | |
Dead band | 0 ... 200 mm | |
Standard target plate | 100 mm x 100 mm | |
Transducer frequency | approx. 85 kHz | |
Nominal ratings | ||
Linearity error | < 40 mm | |
Temperature drift | < +/- 100 mm | |
Time delay before availability | ≤ 700 ms | |
Functional safety related parameters | ||
MTTFd | 431 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED yellow | object in evaluation range | |
LED red/green | CANopen status display | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V | |
No-load supply current | ≤ 50 mA | |
Power consumption | typ. 0.6 W | |
Interface | ||
Interface type | CAN | |
Communication protocol | CANopen | |
Process data | Input: 48 Bit - measured value (distance value) 16 Bit - signal quality 8 Bit - counter-1 16 Bit or counter-2 8 Bit - status register 8 Bit | |
Node ID | programmable | |
Vendor ID | 173 (0xAD) | |
Product code | 50331651 (0x03000003) | |
Transfer rate | 250 kBit/s , programmable 125 ... 1000 kBit/s | |
Termination | external | |
Cycle time | 53.5 ms preset , programmable | |
Min. cycle time | 53.5 ms | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 | |
Communication interface | CiA 310, Ver. 4.2.0 | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
UN/ECE Regulation No. 10 (E1) | Type-approval number: 10R-069608 | |
Ambient conditions | ||
Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | fixed cable with plug | |
Degree of protection | IP68 | |
Material | ||
Housing | PA-GF35 | |
Connector | ||
Number of pins | 6 | |
Connection assembly | Deutsch connector DT04-6P-CE02 Deutsch contact 1060-16-0622 Deutsch wedge W6P | |
Cable | ||
Cable diameter | 7.25 mm ± 0.2 mm | |
Bending radius | > 10 x cable diameter | |
Material | PUR | |
Color | black | |
Number of cores | 5 | |
Core cross section | 0.8 mm2 | |
Length | 352 mm ± 5 mm | |
Mass | 240 g | |
Factory settings | ||
Default setting | counter-1 , 8 Bit | |
Beam width | wide | |
Synchronization | deactivated | |
Node ID | 16 | |
Transfer rate | 250 kBit/s |
Classifications
System | Classcode |
---|---|
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!