Ultrasonic sensor UC500-D1-3K-V7
Brand: Pepperl+Fuchs
Code: UC500-D1-3K-V7
Single head system, Specially for level monitoring in vessels, Large operating voltage range
10 V DC ... 253 V DC
20 V AC ... 253 V AC, 3 relay outputs, Series: -D1, Operating voltage: 10 ... 253 V DC
20 ... 253 V AC , 47 ... 63 Hz, Output type: 3 relay outputs, normally open/closed, selectable, CCC approval: self-declaration, Connection: Female connector, V7 (7-pin), 90°
Wire cross section: ≤1.5 mm2
cable diameter ∅7 ... 9 mm
Datasheet excerpt: Technical data of UC500-D1-3K-V7
Product Description |
---|
Single head system |
General specifications | ||
---|---|---|
Sensing range | 60 ... 550 mm | |
Dead band | 0 ... 60 mm | |
Standard target plate | 100 mm x 100 mm | |
Transducer frequency | approx. 380 kHz | |
Response delay | > 10 s, relay < 1 s, LEDs | |
Indicators/operating means | ||
LED red | LED 1: overfill indication LED 4: underfill indication | |
LED green/yellow | LED 2: overfill warning and normal operation LED 3: normal operation and underfill warning | |
DIP switch | setting of the switch points/operating modes | |
Electrical specifications | ||
Operating voltage | 10 ... 253 V DC 20 ... 253 V AC , 47 ... 63 Hz | |
No-load supply current | < 30 mA with UB = 30 V DC < 110 mA at UB = 10 V DC < 25 mA at UB = 220 V AC | |
Output | ||
Output type | 3 relay outputs, normally open/closed, selectable | |
Range hysteresis | 20 mm | |
Contact loading | 253 V AC/150V DC, 3 A (ohm. load) | |
Life span | electrical: 105 switching cycles with ohmic load (3 A/253 V AC or 3 A/30 V DC) minimum contact load: 100 µA/100 mV DC mechanical: 20 x 106 switching cycles | |
Temperature influence | < 4 % | |
Fusing | ≤ 3 A Slow-blow fuse per output in accordance with IEC 60127-2 Sheet 5 required. Recommendation: after a short circuit, check that the device is functioning correctly. | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 | |
Approvals and certificates | ||
CCC approval | self-declaration | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Housing diameter | 75 mm | |
Degree of protection | IP65 | |
Connection | Female connector, V7 (7-pin), 90° Wire cross section: ≤1.5 mm2 cable diameter ∅7 ... 9 mm | |
Material | ||
Housing | cover: PC housing: PBT threaded flange: stainless steel installation connector/cable socket: PETP | |
Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam | |
Mass | 700 g | |
Note | In case of loss or damage, the cable socket must be replaced by an identical cable socket (type V7-W) from Pepperl+Fuchs! |
Classifications
System | Classcode |
---|---|
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!
Do you want to order a Ultrasonic sensor UC500-D1-3K-V7 with code: UC500-D1-3K-V7?