USi-safety evaluation unit USI-F262-2E5-V19-S2D3
Brand: Pepperl+Fuchs
Code: USI-F262-2E5-V19-S2D3
Evaluation unit exclusively for the ultrasonic sensor system USi-safety, Categorie 3 PL d (EN ISO 13849) for each ultrasonic transducer without redundancy, Multiple device installation possible, no mutual interference (no cross-talk), Safety outputs OSSD, Sensing range: 1 ... 250 cm
typ. 200 cm, Performance level (PL): PL d, Operating voltage: 21 ... 28 V DC
typ. 24 V DC, Interface type: USB 2.0, Output type: safety output OSSD
Normally closed, Power FET PNP
OSSD 1.1 and OSSD 1.2
Datasheet excerpt: Technical data of USI-F262-2E5-V19-S2D3
Product Description |
---|
Evaluation unit exclusively for the ultrasonic sensor system USi-safety |
General specifications | ||
---|---|---|
Type | USi-safety evaluation unit | |
Sensing range | 1 ... 250 cm typ. 200 cm | |
Adjustment range | 1 ... 250 cm | |
Dead band | 1 cm | |
Object size | typ. ∅ 1 cm | |
Transducer frequency | typ. 103 kHz | |
Resolution | 1 cm | |
Target velocity | axial (max.): typ. 2 m/s (up to 2.5 m/s) | |
Repeat accuracy | ± 0 cm | |
Hysteresis | typ. 0 cm (0 up to SP1/10) | |
Temperature influence | automatic or manual temperature compensation available , without temperature compensation: 0.17 %/K | |
Functional safety related parameters | ||
Performance level (PL) | PL d | |
Category | Cat. 3 | |
Reaction time | typ. 100 ms ( 99 ... 660 ms ) | |
Recovery time | typ. 990 ms ( 330 ... 3300 ms ) | |
MTTFd | 316 a | |
Diagnostic Coverage (DC) | 87 % | |
Electrical specifications | ||
Fusing | 2 A , slow | |
Operating voltage | 21 ... 28 V DC typ. 24 V DC | |
No-load supply current | ≤ 150 mA | |
Power consumption | max. 3.6 W | |
Interface | ||
Interface type | USB 2.0 | |
Inputs | ||
Input type | 2 inputs for ultrasonic transducers 1 input for temperature sensor | |
Output 1 | ||
Output type | safety output OSSD Normally closed, Power FET PNP OSSD 1.1 and OSSD 1.2 | |
Switching voltage | max. UB | |
Switching current | 150 mA per output | |
Output 2 | ||
Output type | safety output OSSD Normally closed, Power FET PNP OSSD 2.1 and OSSD 2.2 | |
Switching current | 150 mA per output | |
Output 3 | ||
Output type | Normally open/normally closed switchable, Power FET PNP signal output OUT1 | |
Switching voltage | max. UB | |
Switching current | 150 mA | |
Output 4 | ||
Output type | Normally open/normally closed switchable, Power FET PNP signal output OUT2 | |
Switching voltage | max. UB | |
Switching current | 150 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | IEC 60947-5-2 IEC 60204-1 EN ISO 13849 IEC 61326-3-1:2007 IEC/CISPR 11 group 1, class A | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -30 ... 50 °C (-22 ... 122 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector plug | |
Degree of protection | IP65 | |
Connection | for power supply and outputs: connector plug M12, 8-pin, connection line max. 30 m for temperature sensor: socket M8, 6-pin for ultrasonic transducer: for each socket M8, 3-pin for parameterization: socket Mini USB | |
Material | ||
Housing | diecast aluminum | |
Mass | 450 g | |
Factory settings | ||
Default setting | See the original instructions |
Classifications
System | Classcode |
---|---|
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!
Do you want to order a USi-safety evaluation unit USI-F262-2E5-V19-S2D3 with code: USI-F262-2E5-V19-S2D3?
Leave your request on our website for immediate assistance!