AS-Interface safety module VAA-2E2A-G12-SAJ/EA2L
Brand: Pepperl+Fuchs
Code: VAA-2E2A-G12-SAJ/EA2L
G12 safety module, 2 safety inputs and 2 standard electronic outputs
Datasheet excerpt: Technical data of VAA-2E2A-G12-SAJ/EA2L
Product Description |
---|
G12 safety module, 2 safety inputs and 2 standard electronic outputs |
General specifications | ||
---|---|---|
Node type | Safety node | |
AS-Interface specification | V3.0 | |
Required gateway specification | ≥ V2.1 | |
Profile | S-7.B | |
IO code | 7 | |
ID code | B | |
ID1 code | F | |
ID2 code | 0 | |
UL File Number | E223772 | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Performance level (PL) | PL e | |
Category | Cat. 4 | |
MTTFd | no significant contribution to MTTFd of the overall system | |
PFHd | no significant contribution to PFH of the overall system | |
PFD | no significant contribution to PFD of the overall system | |
Indicators/operating means | ||
LED FAULT | error display; LED red red: communication error or address is 0 red flashing: Output supply overload | |
LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 | |
LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage | |
LED IN | switching state (input); 2 LED yellow | |
LED OUT | Switching status (output); 2 yellow/red LEDs Yellow: output active Red: output overload | |
Electrical specifications | ||
Auxiliary voltage (output) | 24 V DC ± 15 % PELV | |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface | |
Rated operating current | ≤ 50 mA | |
Protection class | III | |
Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral | |
Rated insulation voltage | 40 V | |
Pulse withstand voltage | 0.5 kV | |
Input | ||
Number/Type | 2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or 1 2-channel contact: up to category 4/PL e to ISO 13849-1 Cable length must not exceed 300 m per input. | |
Supply | from AS-Interface | |
Voltage | 20 ... 30 V DC pulsed | |
Current loading capacity | input current limited ≤ 15 mA, overload and short-circuit resistant | |
Output | ||
Number/Type | 2 conventional electronic outputs, PNP | |
Supply | from external auxiliary voltage UAUX | |
Voltage | ≥ (UAUX - 0.5 V) | |
Current | 1.5 A per output , short-circuit protected | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 62026-2:2013+A1:2019 IEC 60947-5-3:1999 | |
Machinery Directive | ||
Directive 2006/42/EC | EN ISO 13849-1:2008 + AC:2009 EN ISO 13849-2:2012 EN 62061:2005 | |
Standard conformity | ||
Insulation coordination | EN 60947-1:2007 | |
Degree of protection | EN 60529:2000 | |
Fieldbus standard | EN 62026-2:2013 | |
Electrical safety | IEC 60947-1, NFPA 79, IEC 60204-1:2007 | |
Emitted interference | EN 61000-6-4:2007/A1:2011 | |
AS-Interface | EN 62026-2:2013+A1:2019 | |
Noise immunity | IEC 62026-2:2008 EN 62061:2005 EN 61000-6-2:2005 | |
Functional safety | ISO 13849-1 (up to category 4/PL e), IEC 61508/IEC 62061 (up to SIL3) | |
Standards | NFPA 79:2007 ER 1 | |
Ambient conditions | ||
Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Relative humidity | 85 % , noncondensing | |
Climatic conditions | For indoor use only | |
Altitude | ≤ 2000 m above MSL | |
Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks | |
Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles | |
Pollution degree | 3 | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Connection | Cable piercing method flat cable yellow/flat cable black inputs/outputs: M12 round connector | |
Material | ||
Housing | PBT | |
Mass | 200 g | |
Tightening torque, cable gland | 0.4 Nm | |
Mounting | Mounting plate |
Classifications
System | Classcode |
---|---|
ECLASS 13.0 | 27272603 |
ECLASS 12.0 | 27242604 |
ECLASS 11.0 | 27242604 |
ECLASS 10.0.1 | 27242604 |
ECLASS 9.0 | 27242604 |
ECLASS 8.0 | 27242604 |
ECLASS 5.1 | 27242604 |
ETIM 9.0 | EC001599 |
ETIM 8.0 | EC001599 |
ETIM 7.0 | EC001599 |
ETIM 6.0 | EC001599 |
ETIM 5.0 | EC001599 |
UNSPSC 12.1 | 39121535 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!