Up to 4 read heads can be connected, DIN rail mounting, Integrated switch, PROFINET interface, Measuring length max. 629 m
Datasheet excerpt: Technical data of WCS-PNG410
General specifications | ||
---|---|---|
Installation | DIN rail mounting | |
Functional safety related parameters | ||
MTTFd | 180 a | |
Mission Time (TM) | 10 a | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Power consumption | ≤ 3.6 W (without read heads) | |
Interface 1 | ||
Connection of | control system | |
Interface type | Ethernet; 100 BASE-TX | |
Protocol | PROFINET IO | |
Transfer rate | 100 MBit/s | |
Data output format | binary code | |
Interface 2 | ||
Connection of | control system | |
Interface type | Ethernet; 100 BASE-TX | |
Protocol | PROFINET IO | |
Transfer rate | 100 MBit/s | |
Data output format | binary code | |
Interface 3 | ||
Connection of | WCS read heads | |
Connectable read heads | WCS...-LS121 , WCS...-LS221 , WCS3B-LS1/2**ES with option ES (Extended Protocol up to 628 m) | |
Interface type | RS-485 | |
Protocol | half duplex | |
Transfer rate | 62.5 kBit/s | |
RS485 termination resistor | switchable | |
Refresh cycle of read head | 1 ms / 10 ms (with extended WCS read head) | |
Standard conformity | ||
Emitted interference | EN 55011, cl. A: 2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Operating temperature | -25 ... 85 °C (-13 ... 185 °F) , no moisture condensation | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | ≤ 80 % | |
Mechanical specifications | ||
Connection type | Interface 1 & 2: RJ-45 socket, 8-pin Interface 3: terminal connection ≤ 2.5 mm2 Interface 4: Terminal connection, 2-pin | |
Housing width | 23 mm | |
Housing height | 100 mm (without plug-in screw connector) 111 mm (incl. plug-in screw connector) | |
Housing depth | 115 mm | |
Degree of protection | IP20 | |
Material | plastic | |
Installation position | any position | |
Mass | approx. 150 g |
Classifications
System | Classcode |
---|---|
ECLASS 13.0 | 27270991 |
ECLASS 12.0 | 27270991 |
ECLASS 11.0 | 27270791 |
ECLASS 10.0.1 | 27270791 |
ECLASS 9.0 | 27270791 |
ECLASS 8.0 | 27270791 |
ECLASS 5.1 | 27270791 |
ETIM 9.0 | EC001852 |
ETIM 8.0 | EC001852 |
ETIM 7.0 | EC001852 |
ETIM 6.0 | EC001852 |
ETIM 5.0 | EC001852 |
UNSPSC 12.1 | 41111945 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!
Do you want to order a WCS interface module WCS-PNG410 with code: WCS-PNG410?
Leave your request on our website for immediate assistance!